Building
Regulation Ventilation Requirements |
| Room |
Extract/Rapid
Ventilation |
Background
Ventilation |
| Kitchens |
Mechanical
ventilation rated as capable of extracting at
a rate of not less than 60 l/sec (or incorporated
within a cooker hood and capable of extracting
at a rate of 30 l/sec) or PSV. Rapid ventilation
by opening window. |
Controllable
and secure ventilation opening having a total
area not less than 4000mm² or by mechanical
ventilation being in addition capable of operating
continuously at nominally one air change per hour. |
| Common
Spaces in Buildings Containing Two or More Dwellings |
No
requirement |
A
ventilation opening with a total area of at least
1/20th of the floor area of the common space.
|
| Bathrooms |
Mechanical
extract ventilation capable of extracting at a
rate not less than 15 l/sec which may be operated
intermittently or PSV. Rapid ventilation by opening
window. |
Controllable
and secure ventilation opening having a total
area not less than 4000mm². |
| Toilets |
Rapid
ventilation by one or more openings with a total
area of at least 1/20th of the floor area of the
room, with at least some part of the opening at
least 1.75m above the floor level; or mechanical
extract ventilation capable of extracting air
at a rate not less than 6 l/sec, which may be
operated intermittently with 15 minutes overrun.
|
Controllable
and secure ventilation opening having a total
area not less than 4000mm² |
| Internal
Toilets |
Mechanical
extract ventilation capable of extracting air
at a rate not less than 6 l/sec, which may be
operated intermittently with 15 minutes overrun.
|
Controllable
and secure ventilation opening having a total
area not less than 4000mm² |
| Utility
Rooms |
Mechanical
extract ventilation capable of extracting at a
rate of not less than 30 l/sec or PSV. Rapid ventilation
by opening window. |
Contollable
and secure ventilation opening having a total
area not less than 4000mm² |
| Habitable
Rooms |
Rapid
ventilation by one or more openings with a total
area of at least 1/20th of the floor area of the
room, with at least some part of the opening at
least 1.75m above the floor level. |
Controllable
and secure ventilation opening having a total
area not less than 8000mm² |