| INLINE
DUCTED |
AD10 |
|
CD100 |
| |
|
|
| AD10KH |
|
CD10KH |
|
|
|
AD10KL |
|
CD10KL |
| |
|
|
A
range of inline fans for use with 100mm ducting.
|
|
|
| AD10
Fan |
| Application: |
100mm
axial duct fan for fitting in loft or flor void with ceiling
mounted grille.
May be ducted up to 2 metres. |
| Performance: |
80m3/h
- 45 dB(A) |
| Electrical: |
220/240V
ac ~ 50 Hz. Power consumption 15 watts. Fuse 3 amp. |
| Models: |
AD10S
standard model no controls
AD10T with adjustable timer 1-25 mins
|
| Fixing: |
100mm
duct, 110mm hole.
Complete kits available with duct plus internal and external
grilles. |
| Pack Information: |
|
|
| CD100
Fan |
| Application: |
100mm
centrifugal fan for fitting in loft or floor void with ceiling
mounted room grille.
May be ducted up to 10 metres |
| Performance: |
110m3/h
- 48 dB(A) |
| Electrical: |
220/240V
ac ~ 50 Hz. Power consumption 26 watts. Fuse 3 amp. |
| Models:
|
CD100 standard
model no controls
CD100T with adjustable timer 1-25 mins |
| Fixing: |
100mm
duct, 110mm fixing hole.
Complete kits available with duct plus internal and external
grilles. |
| Pack Information: |
|
|
| AD10KH
Fan |
| Application: |
The
AD10KH fan incorporates an axial impeller to provide an economical
solution for small bathrooms and short ducts runs. The kit
incorporates in-line duct fans (mounted from the ceiling)
which are connected to internal and external grilles with
100 mm duct. The sensor is connected by cable to the extractor
humidity control. |
| Performance: |
Its
performance of 24 l/s (85 m3/h) will normally provide
an extract rate of 4 air changes an hour in rooms of up to
9 square metres. It exceeds the Building Regulation requirement
of 15 l/s for bathrooms and shower rooms and incorporates
a run on timer making it suitable for use in rooms without
opening windows.
|
| Humidity
Sensor: |
Adjustable |
| Adjustable
Timer: |
1-25
minutes |
| Electrical: |
220/240V
ac ~ 50 Hz. 15 watts. |
| Models:
|
AD10KH |
| Dimensions: |
150
mm high x 150 mm wide x 110 mm over spigots |
| Kit
Includes: |
1 x 100 mm x 600
mm length Aluminum corrugated
1 x 100 mm x 900 mm length Aluminum corrugated
1 x Internal ceiling grill
1 x External vent |
| Pack Information: |
|
|
| CD10KH
Fan |
| Application: |
The
CD10KH fan incorporates a centrifugal impeller, providing
high pressure extract to overcome the resistance of long duct
runs. The unit may be used with up to 10 metres of duct with
bends and offsets. The kit incorporates in-line duct fans
(mounted from the ceiling) which are connected to internal
and external grilles with 100 mm duct. The sensor is connected
by cable to the extractor humidity control. |
| Performance: |
Its
performance of 30 l/s (110 m3/h) will normally
provide an extract rate of 4 air changes an hour in rooms
of up to 12 square metres. It exceeds the Building Regulation
requirement of 15 l/s for bathrooms and shower rooms and incorporates
a run on timer making it suitable for use in rooms without
opening windows. The CD10 may also be used in utility rooms
or kitchens (if installed within 300 mm of the centre line
of the cooker hob). |
| Humidity
Sensor: |
Adjustable |
| Electrical: |
220/240V
ac ~ 50 Hz. 26 watts. |
| Models:
|
CD10KH |
| Dimensions: |
150
mm high x 150 mm wide x 2200 mm over spigots |
| Kit
Includes: |
1 x 100 mm x 600 mm length
Aluminium corrugated
1 x 100 mm x 3 metre length Aluminium/Polyester with wire
spiral support.
1
x Internal ceiling grill
1 x External vent |
| Pack Information: |
|
|
| AD10KL
Fan |
| Application: |
Low
profile extract grille combines ventilation with lighting.
With the 230 volt fan and transformer safely away from the
water and splashing, in the loft or ceiling void, the system
operates quietly and unobtrusively extracting steam and moisture
at source. An extraction rate of 85m3/h meets the
Building Regulations for bathrooms and toilets. |
| Performance: |
85
m3/h (24 l/s) |
| Fan
Electrical: |
220/240V ac ~ 50Hz 17 watts
|
| Light
Electrical: |
12v ~ 50Hz ac 50 watts |
| Transformer: |
230V/12V ac ~ 50Hz 20-60 VA
|
| Models:
|
AD10KL
AD10KLT |
| Dimensions: |
150 mm x 150 mm x 110
mm over spigots
|
| Kit
Includes: |
1
x 100 mm x 600 mm length Aluminium corrugated
1 x 100 mm x 3 metre length Aluminium/Polyester with wire
spiral support.
1 x Internal ceiling grill with light
1 x External vent
|
| Pack Information: |
|
|
| CD10KL
Fan |
| Application: |
Low
profile extract grille combines ventilation with lighting.
With the 230 volt fan and transformer safely away from the
water and splashing, in the loft or ceiling void, the system
operates quietly and unobtrusively extracting steam and moisture
at source. An extraction rate of 80m3/h meets the
Building Regulations for bathrooms and toilets. |
| Performance: |
110
m3/h (30l/s) |
| Fan
Electrical: |
220/240V ac ~ 50Hz 26 watts
|
| Light
Electrical: |
12v ~ 50Hz ac 50 watts |
| Transformer: |
230V/12V ac ~ 50Hz 20-60 VA
|
| Models:
|
CD10KL
- Standard kit
CD10KLT - Kit with liner |
| Dimensions: |
150
mm x 150 mm x 220 mm over spigots
|
| Kit
Includes: |
1
x 100 mm x 600 mm length Aluminium corrugated
1 x 100 mm x 3 metre length Aluminium/Polyester with wire
spiral support.
1 x Internal ceiling grill with light
1 x External vent |
| Pack Information: |
|
|
|